Within a well balanced three period system or for the duration of regular or issue, the sum with the vector of each and every phase present-day is equal to zero. Or in mathematical way:
この地絡電流が流れ続けているところで、零相変流器へ流れる電流をご覧下さい。零相変流器のところを流れる電流のバランスがくずれています。これによって零相変流器2次側には電流が流れるということです。
最後にここまでのおさらいとしてもう一度変流器と零相変流器の違いを示します。
電気の仕事を始めたばかりの人に役立つサイトを目指しますのでよろしくお願いいたします。
Suited to electricity transmission and distribution programs and intended to perform with measuring or monitoring devices, or with protecting relays, these bushing CTs (BCTs) can even be used with GIS or in conjunction with power transformers bushings. Insulation tape or epoxy resin as insulation material.
Designed to defend the power procedure in opposition to leakage and earth faults, these zero-section existing transformers (ZCT) can be found in numerous window diameters. Epoxy-Solid coil. CIC is definitely an industrial grade present-day transformers, voltage transformers, distribution transformers, epoxy insulators and electric power capacitors manufacturer from Taiwan. With in excess of forty five many years of experience and technological know-how collaboration with Germany's MWB, CIC is ISO certified and delivers products and solutions recognized for dependability in many industrial applications.
네이버 여행 서비스를 이용해 주신 여러분께 감사드리며, 더 좋은 서비스로 보답할 수 있도록 노력하겠습니다.
このように電流の不平衡が生じることで地絡検出が可能なのですが、シールドがあることで地絡しても不平衡が起きなくなります。
จำหน่ายอุปกรณ์ไฟฟ้าแรงต่ำ-แรงสูงทุกชนิด อุปกรณ์ไฟฟ้าบ้าน อาคาร โรงงาน
Symmetrical Main Structure: HY-ZCT ordinarily make use of a symmetrical core design to ensure equivalent magnetic coupling for all 3 phases. This style reduces the mistake due to magnetic unbalance and improves the precision of zero sequence present measurement.
This triggers a trip system, properly isolating the faulted section to forestall injury and guarantee security.
Frequency response: ZCT is intended this site to run in excess of a variety of frequencies, usually from 50Hz to 400Hz, which makes them ideal for use in a variety of apps.
Even so, every time a ground fault takes place, this stability is disrupted. The fault generates a magnetic flux from the ring core on the ZSCT, inducing a voltage around the secondary facet that activates the security relay.
Due to the fact we have been addressing the current transformer, We're going to seek to put into action Kirchhoff’s Present-day Law listed here. Since a three stage process is A 3 AC existing with shifted period. Within the KCL, we know that: